High temperature installation line
1: product characteristics and uses
The fluorine plastic insulation installation line has excellent properties such as wide temperature range, oil resistance, abrasion resistance, acid and alkali resistance, various chemical reagents, aging resistance and no combustion. It can be used for electrical connection of electrical appliances, meters and equipment in high and low temperature and all kinds of harsh environment.
Due to the advantages of small diameter, light weight, high temperature resistance, vibration resistance, impact resistance and easy installation, the fluorine plastic insulation installation line can be used as aviation wires, including various kinds of wires and cables for aircraft and satellites.
The silicone rubber insulation installation line has the characteristics of heat resistance, cold resistance, corrosion resistance and softness. The product has excellent anti-aging performance and long service life, and can be used for electrical connection of mobile electrical appliances and meters in harsh environment such as high temperature and low temperature.
Two: product implementation standards
Q/SLTZH005.1
Three: usage characteristics
1. AC rated voltage: AF U0/U:300/500
2. working temperature: the silicon rubber insulation installation line does not exceed 180 degrees.
F46 insulation installation line not exceeding 200 c
PFA insulation installation line not exceeding 260 C
3. ambient temperature: -60 C
4. the allowable bending radius of the wire is not less than 4 times of the outer diameter of the cable.
Four: basic models and names
Table 1
Model | Product name | Normal service temperature |
AF-200 | Silver coated copper core polyfluoroethylene propylene insulation installation line | Two hundred |
AFP-200 | Silver coated copper core polyfluoroethylene propylene insulation shielding installation line | Two hundred |
AFFP-200 | Silver coated copper core polyfluoroethylene propylene insulation and sheath shielding installation line | Two hundred |
AF-260 | Silver coated copper core soluble PTFE insulation installation line | Two hundred and sixty |
AFP-260 | Silver coated copper core soluble PTFE insulated shielding installation line | Two hundred and sixty |
AFFP-260 | Silver coated copper core soluble PTFE insulated and sheathed shielding installation line | Two hundred and sixty |
AF46 | (tin plated) copper core F46 insulation installation line | Two hundred |
AF46R | (tin plated) copper core F46 insulated installation flexible cord | Two hundred |
AF46RP | Tin plated copper core F46 insulated shield installation flexible cord | Two hundred |
AGR | (tin plated) copper core silicone rubber insulation installation line | One hundred and eighty |
AGRP | (tin plated) copper core silicone rubber insulation installation line | One hundred and eighty |
Remarks: silver plated conductors are multi share soft structures.
Five: code name and meaning
Table 2
Code name | Code meaning |
A | Installation line and installation cable |
G | silicon rubber |
F, F46 | Perfluoroethylene propylene |
P | Copper braided shield |
R | Stranded conductor |
200, 260 | Temperature tolerance grade |
Six: main technical indicators
1. finished wire conductor (class R) DC resistance (comply with GB3956 regulations)
Nominal cross section | 20 degree DC resistance is less than or equal to /km | Nominal cross section | 20 degree DC resistance is less than or equal to /km | ||
Tin plating / nickel plating | Plate with silver | Tin plating | Tin free | ||
Zero point zero six | Three hundred and eighty-four | Three hundred and sixty-two | Two | Nine point four | Nine point one |
Zero point one two | One hundred and sixty-three | One hundred and forty-nine | Two point five | Eight point two one | Seven point nine |
Zero point two | Ninety-five | Ninety-one point four | Four | Five point zero nine | Four point nine |
Zero point three | Seventy-one point two | Sixty-eight point five | Six | Three point three nine | Three point two seven |
Zero point three five | Fifty-six | Fifty-four | Test voltage: 0.06-0.3-1500V/5min 0.35-1.0-2000V/5min 1.5-6-2500V/5min | ||
Zero point five | Forty point one | Thirty-eight point six | |||
Zero point seven five | Twenty-six point seven | Twenty-five point seven | |||
One | Twenty | Nineteen point three | |||
One point five | Thirteen point seven | Thirteen point two |
The insulation resistance is not less than 100000M ohm /KM at 2.20 C.
Seven: basic cable specifications and structural parameters
Line core * nominal cross section (mm2) | Conductor structure (root number * diameter) (B/R) Mm | Large outer diameter of cable (mm) | Reference weight (kg/km) | ||||
AF-200 AF-260 | AFP-260 | AFFP-200 AFFP-260 | AF-200 AF-260 | AFP-260 | AFFP-200 AFFP-260 | ||
Zero point zero six | 7/0.10 | One | One point four | Two point one | Two point one | Five | Nine |
Zero point one two | 7/0.15 | One point two | One point six | Two point three | Three point two | Seven point six | Twelve point one |
Zero point two zero | 7/0.20 | One point four | One point nine | Two point six | Four point three | Eight point seven | Thirteen point nine |
Zero point three zero | 7/0.23 | One point five | Two | Two point eight | Five | Ten point two | Sixteen point six |
Zero point three five | 19/0.15 | One point six | Two point one | Two point nine | Six point six | Twelve point six | Nineteen point two |
Zero point five zero | 19/0.18 | One point eight | Two point three | Three point three | Eight point one | Fourteen point two | Twenty-three point five |
Zero point seven five | 19/0.23 | Two | Two point six | Three point six | Eleven point eight | Twenty point seven | Thirty-one point one |
One | 19/0.26 | Two point two | Two point eight | Three point eight | Fourteen point three | Twenty-three point two | Thirty-four point three |
One point five | 19/0.32 | Two point six | Three point three | Four point three | Twenty-one point five | Thirty-two point five | Forty-five point three |
Two | 19/0.37 | Two point nine | Three point six | Four point six | Twenty-seven point eight | Thirty-nine point two | Fifty-three |
Two point five | 49/0.26 | Three point five | Four point one | Five point two | Thirty-six point four | Fifty | Sixty-nine point one |
Four | 49/0.32 | Four point two | Four point nine | Six point two | Fifty-seven point two | Seventy-five point two | Ninety-nine point seven |
Six | 49/0.39 | Four point nine | Five point six | Seven | Eighty point two | One hundred and four | One hundred and thirty-four |
Remarks: AGR specifications and structural parameters refer to JGG silicone rubber cable data.