Welcome to Anhui Tiankang mechanical and Electrical Equipment Co., Ltd!
    Chinese |English |Sitemap|18019899982
14928493723312.jpg

Explosion proof electric contact pressure gauge

YX-160-B explosion-proof electrical contact pressu
  • Tel:18019899982
  • Fax:0550-7989666
  • Mail:tkjd@tiankang.com
Description

1. The principle of product structure
YX-160-B explosion-proof electrical contact pressure gauge is composed of flameproof enclosure, measuring system, electrical contact group, regulating device and outlet box. The flameproof enclosure of the pressure gauge has good flameproof performance. Therefore, due to the influence of sparks or arcs in the normal working process, the explosion-proof electric contact pressure gauge can not only withstand the explosive pressure generated by the explosive gas mixture inside the shell once the explosion occurs, but also effectively prevent the resultant heat energy from spreading smoothly, and can only be moved along the inside of the shell. The tiny gaps in the joint surface diffuse slowly outward. At this time, the instantaneous temperature passed to the outside of the shell has been reduced to below the ignition temperature of the explosive gas mixture, so it will not cause detonation.
The working principle of the explosion-proof electric contact pressure gauge is based on the elastic deformation of the detecting element (the spring tube in the measuring system), which drives the contacts in the electrical contact group to generate corresponding actions (closed or disconnected) through mechanical transmission so as to enable the circuit in the voltage control system to be connected or disconnected, so as to realize the purpose of automatic control alarm and on-site instructions.

Two. Main technical indicators
Accuracy level: 1.5
Scale range: 0 ~ 0.16; 0~0.25; 0 ~ 0.4; 0 ~ 0.6; 0~1; 0 ~ 1.6; 0~2.5; 0~4; 0~6; 0~6; 0~6; 0~6; 0~60; -0.1 ~ l; -0.1 ~ -0.1; -0.1 ~ -0.1; -0.1 ~; -0.1~0.9; -0.1 ~ *; -0.1 ~ 2.4MPa
Control mode: upper and lower limit slow contact switch.
Zui high working voltage: DC 220V or AC 380V;
Contact power: 10VA
Working position: vertical installation
The environmental conditions are: -10 ~ 50 C, the relative humidity is not greater than 80%, and the explosive mixture should belong to group II B below T4. The working vibration and the sharp fluctuation of the tested medium have no influence on the reliable movement of the instrument contacts.
Temperature effect: the indication value is not greater than 0.4%/10 C, and the setting point is not greater than 0.6%/10 C (the temperature deviation is 20 + 5 C).
Insulation strength: 50Hz sine alternating current 2000V takes one minute.
Weight: 6kg
Three. Flameproof joint type and its basic parameters.

Shell volume V (L)

> 0.5

Joint face type

plane

Cylinder (movable part)

Zui small effective length Lmm for flameproof joints

Fifteen

Screw through hole edge to flameproof joint surface Zui small effective length L1

Eight

Flameproof joint Zui large gap or diameter difference Wmm

Zero point one five

Surface roughness of flameproof joint surface Ra

Three point two

One point six

Note: examples of effective length and gap width of flameproof joints can be seen in the schematic diagram of flameproof enclosure structure.

Flameproof enclosure and pressure system and other components and materials.

Part name

Material designation or designation

Part name

Material designation or designation

Shell cap
Outlet box

ZL102
(or ZL-102, ZL-101)

Thin washer

L3

Joint

Twenty

Axle sleeve

QAJ9-2

Spring tube

3J53

Observation window

Organic glass



Note: the material of the observation window of the explosion-proof electric contact pressure gauge has an impact strength of not less than 4J. Once the observation windows are damaged, they are not allowed to be used.



Browse:
Return To The Top

分享到: