Fire resistant cable

high and long-term working temperature of cable (
  • Tel:18019899982
  • Fax:0550-7989666
  • Mail:tkjd@tiankang.com
Description

1. AC rated voltage: U. /U (V series: 600/1000V, K series: 450/750V, B series: 450/750V).

2. high and long-term working temperature of cable

(1) vinylidene fluoride insulation and sheath: two at 70 C and 105 C; XLPE insulation: 90 C;

(2) Fluorocarbon insulation and sheath: two kinds at 220 and 260 degrees; fluoroplastic insulation and 105 degree flame retardant polyvinyl fluoride jacket: two at 90 and 125 degrees Celsius.

(3) low halogen and low smoke flame retardant PVC insulation and sheath: 70 degrees; halogen free low smoke flame retardant polyolefin insulation and sheath: 90 and 125 degrees two.

3. ambient temperature:

(1) flame-retardant PVC insulation and sheath: fixed at -40 C; unfixed -15 C;

(2) Fluorocarbon insulation and sheath: fixed at -60 C; fixed at -20 C;

4. the safe laying temperature of cables should not be below 0 C.

5. fire resistance characteristics:

Comply with GA 306.2-2007 and GB/T 19216.21-2003 regulations

Flame temperature, flame temperature 950 C -1000 C, flame temperature 750 C -800 C

Burning time and burning time 90min (recommended) burning time 90min (recommended)

Additional voltage rated voltage (Zui small 100V) rated voltage (Zui small 100V)

Fire resistance class A (grade IA ~IVA) I~IV class

6. the allowable bending radius recommended for installation: the non armored and braided shielded cables shall be not less than 6 times the outer diameter of the cables.

The steel tape armored cable should not be less than 12 times of the outer diameter of the cable.

Fluorine plastic insulation and sheathing material cable should not be less than 8 times of the outer diameter of cable.

Common models


Model
Name
Remarks
NA-YJV/NB-YJV
XLPE insulated PVC sheathed A (B) class fire-resistant power cables
It can be laid in fire resistant indoor, tunnel and piping.
NA-YJV22/NB-YJV22
XLPE insulated steel tape armored PVC sheathed A (B) class fire resistant power cable
It is suitable for laying underground when fire resistance is required, and is not suitable for laying in pipelines.
WDNA-YJY/WDNB-YJY
XLPE insulated polyolefin sheathed A (B) halogen free low smoke fire resistant power cable
It can be installed in indoor, tunnel and piping for halogen free, low smoke and fire resistant requirements.
WDNA-YJY23/WDNB-YJY23
XLPE insulated steel tape armored polyolefin sheathed A (B) halogen free low smoke fire resistant power cable
It is suitable for laying underground without halogen, low smoke and fire resistance, and is not suitable for laying in pipelines.