Intelligent target flowmeter
- Tel:18019899982
- Fax:0550-7989666
- Mail:tkjd@tiankang.com
Description
I. Introduction
The intelligent target flowmeter is based on the traditional diaphragm type target flowmeter. The new strain sensor is applied to the target flowmeter. At the same time, the new digital technology and microelectronic technology are applied to process the detected sensing signal into 4 to 20mA signal output which is proportional to the flow rate. Meanwhile, the traditional target flow is displayed by displaying the instantaneous flow and accumulative flow simultaneously through two large liquid crystals. Both structure and performance have been improved significantly. The smart strain target flowmeter is applying for the national patent.
Two, product characteristics
High temperature and high pressure: from -80 to +200, the pressure can reach 10MPa
Suitable for all kinds of caliber: Phi 15 ~ 1500mm
It is suitable for measuring liquid, gas and steam.
Low velocity medium can be measured, and the flow rate can be measured at more than 0.1m/s (the Reynolds number is greater than 1000).
A medium with large viscosity and sediment.
Accurate measurement, high accuracy, up to 0.2% (special order).
The pressure loss is small, which is half of the standard orifice, and the big diameter decreases obviously.
Nominal caliber and pressure | Flange type: DN15 ~ DN300mm (pressure 1.6 ~ 10MPa) |
Clamping type: DN15 ~ DN300mm (pressure 1.6 ~ 10MPa) | |
Insert: DN150 ~ DN1500mm (pressure 1.6 ~ 10MPa) | |
Threaded type: DN15 ~ DN50mm (pressure 1.64MPa) | |
Accuracy | + 0.5% + + 2.5%FS standard: + 1.0%FS |
Medium temperature | - 40 C to +200 C (over 100 C plus heat sink, over 200 c or less than -30 C plus jacketed device) |
ambient temperature | -40 ~ +85 C (liquid crystal will not damage). The liquid crystal works normally at -30 C to +80 C. |
Power supply | 24VDC two-wire system 4 to 20mA (12VDC to 32VDC) |
Battery type: 3.6V@7.5AH lithium battery, sustainable use for three years | |
signal output | 4 ~ 20mA |
Measuring tube material | Stainless steel 304, 316 or others |
Explosion proof sign | Intrinsically safe ExiaIICT5, flameproof ExdIIBT6 |
Cable interface | Flameproof 1/2NPT internal thread, other M20 * 1.5 internal thread |
LCD | Instantaneous flow range: 0~50000 (with decimal point). |
Cumulative flow display value range: 0~99999999 (with decimal point) automatic reset | |
Shell material | Cast aluminum |
Load characteristics | RLmax=50* (supply voltage -12) @24V |
Protection level | IP65 |
Instrument type | LB-1 | LB-2 | LB-3 | LB-4 |
signal output | nothing | 4-20mA | 4-20mA | 4-20mA |
Power supply | lithium battery | 24VDC + 15% | 24VDC + 15% | 24VDC + 15% |
communication interface | nothing | Optional RS485 | Optional RS485 | Optional RS485 |
Accuracy grade | Liquid: Level 1 Gas: Level 1 Steam: grade 1.5 | Liquid: Level 1 Gas: Level 1 Steam: grade 1.5 | ||
Monitor | Yes | Yes | ||
Instrument material | 304SS | 304SS | ||
Explosion proof grade | Optional ExiaIICT5 or ExdIIBT6 | Optional ExiaIICT5 or ExdIIBT6 | ||
Protection level | IP65 | IP65 | ||
Overall power consumption | < 1W | < 1W | ||
Instrument access | DN15 ~ DN1500 | DN15 ~ DN1500 | ||
Installation mode | Thread, flange type, clamping type, insert type. | Thread, flange type, clamping type, insert type. | ||
Withstand voltage grade | Optional 1.6MPa or 2.5MPa | Optional 1.6MPa or 2.5MPa | ||
Medium temperature | -40 C to 250 C, -40 C to 350 C | -40 C to 250 C, -40 C to 350 C | ||
ambient temperature | -20 ~ 60 C | -20 ~ 60 C |