Diffused silicon pressure transmitter
- Tel:18019899982
- Fax:0550-7989666
- Mail:tkjd@tiankang.com
Description
2088 the diffused silicon pressure transmitter has the characteristics of reliable operation, stable performance, convenient installation and use, small size, light weight and high performance price ratio. It can be widely used in various positive and negative pressure measurements.
2088 the diffused silicon pressure transmitter adopts the imported diffused silicon or ceramic piezoresistive sensor as the pressure detecting element, and the signal of the sensor is transformed into a 4-20mA or 0-10mA uniform output signal through a high performance electronic amplifier.
The 2088 series pressure transmitter adopts imported diffused silicon or ceramic core as the pressure detecting element, and the sensor signal is transformed into a 0~ 10mA or 4~ 20mA uniform output signal through a high performance electronic amplifier. It can replace the traditional remote pressure gauge, Holzer element and differential transmitter, and has the performance of DDZ- I and DDZ- II transmitter. It can be used in conjunction with all kinds of moving coil indicator, digital pressure gauge and electronic potentiometer, and can also be used in conjunction with various automatic control systems or computer systems.Widely used in power, petrochemical, machinery, metallurgy and other industries and various energy metrology.
The main features of the diffused silicon pressure transmitter are overload resistance and impact resistance. The overpressure can reach several times of the range. Even a hard object directly hits the measuring element without damaging it and has no effect on the measurement accuracy.
The stability is high, which is better than 0.1% full scale per year. This technical index has reached the level of intelligent pressure instrument, and the temperature drift is small. As a result, the medium fluid in the pressure measuring element is cancelled, so the sensor not only obtains very high measurement accuracy, but also has little influence on the temperature gradient.
Pressure transmitter has wide applicability, easy installation and maintenance, and can be installed at any location.
Nonlinear error: 0.25 level less than or equal to 0.25%FS
Application scope | Measurement of pressure in industrial process control system |
Measured medium | Various media compatible with 316L |
Range (gauge pressure, absolute pressure) | 0 ~ 10kPa, 0 ~ 16kPa, 0 ~ 25kPa, 0 ~ 40kPa, |
overload | For measuring range less than 10MPa, 2 times. |
Accuracy (including linearity, hysteresis, repeatability) | 0.25%, 0.5% |
Working temperature range | Measured medium: - 60 ~ + 0. |
Compensation temperature range | 40 to + 80 degrees centigrade |
Influence of environmental temperature changes | 1, for range > 0.06MPa: |
stability | < 0.2%FS / year |
output | 4 to 20mADC two wire system |
Power supply | 12 ~ 45VDC (to consider load); |
Electrical interface | M20 * 1.5 or ZG1/2 |
Process connector | M20 x 1.5 or 1/2 NPT, or according to user requirements |
Power waste | < 1W |
Enclosure protection level | IP65 |
weight | < 1.5kg |