Welcome to Anhui Tiankang mechanical and Electrical Equipment Co., Ltd!
    Chinese |English |Sitemap|18019899982
14928508262151.jpg

Armored thermocouple

The WR K armored thermocouple has the advantages o
  • Tel:18019899982
  • Fax:0550-7989666
  • Mail:tkjd@tiankang.com
Description

I. Product Overview

The WR K armored thermocouple has the advantages of bending, high pressure resistance, fast response and strong durability. The armored thermocouple is the same as the assembled thermocouple. As a sensor for measuring temperature, the armored thermocouple usually matches the display of the thermocouple and the display instrument, the recorder and the electronic regulator. At the same time, the armoured thermocouple can also be used as the temperature sensing element of the assembled thermocouple. The armored thermocouple can directly measure the temperature of liquid, steam and gas medium and solid surface in various production processes ranging from 0 to 1100 degrees.
Two. Main technical indicators
Temperature range and accuracy

category
Code name
Graduation
Outer diameter of casing mm
Common temperature and temperature
Use temperature c
Allowable deviation
Measuring range C
Allowable difference
Platinum rhodium 10- platinum
WRPK
S
Greater than or equal to 3
One thousand and one hundred
One thousand and two hundred
0-1200
+ 1.5 or + 1.5%t
Nickel chromium copper nickel
WREK
E
Greater than or equal to 3
Six hundred
Seven hundred
0-700
+ 2.5 or + 0.75%t
Nickel chromium nickel silicon
WRNK
K
Greater than or equal to 3
Eight hundred
Nine hundred and fifty
0-900
+ 2.5 or + 0.75%t
Cu Cu Ni
WRCK
T
Greater than or equal to 3
Three hundred and fifty
Four hundred
Less than -200
No provision
-40-350
+ 0.75%t
Fe Cu Ni
WRFK
J
Greater than or equal to 3
Five hundred
Six hundred
0-600
+ 2.5 or + 0.75%t

Note: "t" is the value of the measured temperature.  
T grading products need to consult with our factory for ordering.

Thermal response time of armored thermocouple
When the temperature changes step by step, the time required for the thermocouple output to change to 50% of the step change is called thermal response time. It is expressed by tau 0.5.
The thermal response time of the armored thermocouple is not greater than that of the following table:

Thermal response time 0.5S
Shell type
Insulation type
Casing diameter (mm)
Two
Zero point four
Zero point five
Three
Zero point six
One point two
Four
Zero point eight
Two point five
Five
One point two
Four
Six
Two
Six
Eight
Four
Eight


Browse:
Return To The Top

分享到: